86BYG

Hybride Schrittmotoren 86BYG

Datenblatt herunter laden
Allgemeinspezifikationen für Schrittmotoren 86BYG:
Schrittwinkel 1.8° ± 5%
Erwärmung Δt = max. 80°C
Umgebungstemperatur -20°C – 50°C
Isolationswiderstand 100MΩ min. 500V DC
Spannungsfestigkeit 500V AC/1 min
Electrical specification:
Model   Motor Length Holding Torque Lead Wires Rated Current Phase Resis- tance Phase Induc- tance Rotor Inertia Detent Torque Shaft ∅d Motor Weight
(mm) (N⋅m) (A) (Ω) (mH) (kg⋅cm2) (N⋅cm) (mm) (kg)
86BYG250A-04 B 63 3 4 4.0 1.5 6.5 0.68 8.8 8 1.55
86BYG250A-05 B 63 2.6 4 4.0 1.0 3.2 0.68 8.8 9.5 1.55
86BYG250A-06 B 63 2.6 4 4.0 1.08 4.4 0.68 8.8 10 1.55
86BYG450A-03 U 63 1.7 8 3.6 0.6 1.7 0.68 8.8 9.5 1.55
BS 2.4 2.5 1.2 6.8
BP 2.4 5.1 0.3 1.7
86BYG450A-05 U 63 1.9 8 2.0 2.65 5.4 0.68 8.8 9.5 1.55
BS 2.7 1.4 5.3 21.6
BP 2.7 2.8 1.33 5.4
86BYG250B B 95 4.1 4 3.0 1.6 9.0 1.3 15.7 9.5 2.61
86BYG450B-01 U 95 2.8 8 4.0 0.75 3.5 1.3 15.7 9.5 2.61
BS 3.9 2.8 1.5 14
BP 3.9 5.7 0.38 3.5
86BYG450B-04 U 95 4.5 8 5.0 0.72 2.85 1.3 15.7 9.5 2.61
BS 6.4 3.5 1.44 11.4
BP 6.4 7.0 0.36 2.85
86BYG250HB B 95 9.1 4 4.0 3.8 20 2.9 24.5 12 2.61
86BYG250HB-01 B 95 6.0 4 5.0 0.73 3.4 2.9 24.5 12 2.61
86BYG250HC B 127 9.5 4 5.0 0.7 3.8 4.6 34.3 12 2.61

Anmerkungen:
U = Unipolarer Anschluss
B = Bipolarer Anschluss
BS = Bipolarer serieller Anschluss
BP = Bipolarer paralleler Anschluss

Alle Schrittmotoren sind mit zweitem Wellenende lieferbar.

Mechanische Abmessungen:
Anschlussdiagramm
Technische Änderungen vorbehalten 2012/ 02
Deutsch